Construction Tool

ADA Clearance Checker

Check doors, routes, turning space, clear floor space, thresholds, and ramps against the most common 2010 ADA Standards clearances — with instant pass / fail badges for each.

Compliance Summary
6 of 6
All checks pass
Door clear width
Requires ≥ 32 in (measured 90° open, face of door to stop) · you entered 34 in
Pass
Accessible route / corridor width
Requires ≥ 36 in · you entered 42 in
Pass
Turning space diameter
Requires ≥ 60 in (or 60 × 60 in T-turn) · you entered 60 in
Pass
Clear floor space
Requires width ≥ 30 in AND depth ≥ 48 in · you entered 30 × 48 in
Pass
Threshold height
Requires ≤ 0.5 in · you entered 0.5 in
Pass
Ramp slope
Requires ≤ 1:12 (run per 1" rise ≥ 12) · you entered 1:12
Pass

Based on the 2010 ADA Standards for Accessible Design. Also verify ICC/ANSI A117.1 and your local code, since amendments vary — confirm requirements with your building official or accessibility consultant.

Common ADA Clearance Requirements

The 2010 ADA Standards set minimum clearances that make spaces usable by people who use wheelchairs and other mobility devices. Doorways need at least 32 inches of clear width measured with the door open 90 degrees, accessible routes need 36 inches, and a wheelchair turning space needs a 60-inch circle or a 60-by-60-inch T-shaped space.

A clear floor space for a stationary wheelchair is 30 by 48 inches, thresholds at doorways are limited to 1/2 inch high (beveled), and ramps may not exceed a 1:12 running slope — one inch of rise for every twelve inches of run. This checker covers those high-frequency items; full compliance involves many more provisions for reach ranges, restrooms, and signage.

Frequently Asked Questions

What is the minimum ADA door width?

An accessible doorway must provide at least 32 inches of clear width, measured from the face of the door to the stop with the door open 90 degrees. Doors in a series and other conditions can require more.

What is the ADA turning radius?

A wheelchair turning space must be either a 60-inch diameter circle or a 60-by-60-inch T-shaped space, allowing a person using a wheelchair to make a 180-degree turn.

What is the maximum ADA ramp slope?

The maximum running slope for a ramp is 1:12, meaning one inch of vertical rise for every twelve inches of horizontal run. Ramps also need level landings and, in most cases, handrails.